high-quality prestressed steel wire and steel strand Manufacturer & Supplier

Home / News / Never Too Late to Know /

How to Prevent Corrosion of Prestressed Concrete Steel Strands?

How to Prevent Corrosion of Prestressed Concrete Steel Strands?

Issue Time:2021-07-15
the anti-corrosion measures for prestressed concrete steel strands


Prestressed steel is stress corrosion under the combined action of stress and corrosion (in the category of galvanic corrosion). It is characterized by the formation of cracks in the metal first, and after the occurrence of internal cracks, stress concentration will be formed, accelerating the development of cracks. Therefore, the anti-corrosion of prestressed steel wires and steel strands is a major issue related to the quality and life of the project, and we must pay sufficient attention to it. The following are the anti-corrosion measures for prestressed concrete steel strands.

The factors affecting stress corrosion are mainly composed of internal and external components, such as the composition and state of the metal, the nature and size of the load, the surrounding conditions of the mental stress, and the physical and chemical properties of the medium. From the internal conditions of the steel, it is required that this type of steel must be refined outside the furnace, and the content of impurities, phosphorus, and copper should be strictly controlled, and the surface defects of the wire rod should also be strictly controlled.

The anticorrosive plating (coating) steel of prestressed steel is always in service under the condition of corrosive medium. Therefore, the manufacturer should deal with it in advance to isolate (or slow down) the medium corrosion of the steel base.

A non-metal protective layer (coating)

The non-metallic coatings of the non-metallic protective coating steel strand for prestressed concrete mainly include plastic, epoxy resin, and anti-corrosion grease. Because of its simple process equipment, low investment, and easy deployment. However, the anti-aging problem of non-metallic coating has not been solved, and its mechanical properties are much lower than that of metal coating. Therefore, the scope of application is limited.

Chemical protection layer

The chemical protective layer forms a protective layer on the metal surface through a chemical method, such as passivation of the zinc layer and oxidation of the aluminum layer. Iron-based phosphating, etc. This type of protective layer is often not used as a single steel strand protective layer but is used in conjunction with the metal coating.

A metal protective layer (plating layer)

In the electrochemical corrosion of the metal protective coating, the metal in the anode is first dissolved. For this reason, the surface of the steel strand is plated with iron and active metals, such as zinc and aluminum. In the environment of corrosive medium, the zinc is first dissolved to protect the iron base, which is called anode coating protection. Cathodic protection (such as tin plating) is rarely used in prestressed steel. Because galvanizing (or zinc-aluminum alloy) has good results and mature process equipment in metal anti-corrosion. Therefore, it is also widely used with prestressed steel.

Prestressed concrete steel strands work under high pressure, and stress corrosion will directly affect their service life and thus the life of construction projects. Therefore, it is very important to have an excellent anticorrosive coating for prestressed concrete steel strands. If you want to know more about prestressed concrete strands after reading the above content, you can contact us for a more comprehensive solution.

As a professional manufacturer of prestressed concrete products, we have won praise and trust from many customers with our excellent technology and high-quality products. We have an experienced manufacturing team and fully control the quality of our products, so we can provide customers with high-quality and safe products. And we can also provide thoughtful one-stop service and develop effective solutions according to customer needs. If you are interested in our prestressed concrete strands, please contact us immediately!
pdf document download
  • ASTM A416 Chunpeng 7 wire prestressed concrete strand

    ASTM A416 Chunpeng 7 wire prestressed concrete strand

    2021-03-05
  • PE coated PC strand

    PE coated PC strand

    2021-03-05
  • pc strand

    pc strand

    2021-03-05
  • PC WIRE

    PC WIRE

    2021-03-05
Learn more from our FAQ
  • Can I visit you?

    Answer:

    Sure, If you would like to visit our factory, please contact us to make an appointment.

    More details
  • How can I know how my order is being done?

    Answer:

    We will inspect and test all items in order to avoid damage and missing parts before shipping. The detailed inspection pictures of the order will be sent to you for your confirmation before delivery.

    More details
  • Can you give warranty of your products?

    Answer:

    3.Yes, we extend a 100% satisfaction guarantee on all items. Please feel free to feedback immediately if you are not pleased with our quality or service. For the overseas orders, we provided emails with details including pictures or short video to you to confirm the quality before the shipment.

    More details
  • 4.How long of your delivery time?

    Answer:

    Generally need 5-10 days if it is in stock. Or need 15-20 days if it is out of stock.

    More details
Request a Quote
Fill all information details to consultwith us to get sevices from us
*Email
*Tel
*Title
*Content
Join to chunpeng to get information